Badger Meter Recordall Series Manuals & User Guides. User Manuals, Guides and Specifications for your Badger Meter Recordall Series Measuring Instruments. Database contains 1 Badger Meter Recordall Series Manuals (available for free online viewing or downloading in PDF): Operation & user’s manual. View and Download Badger Meter Recordall Series user manual online. Industrial Meters Nutating Disc Meter. Recordall Series Measuring Instruments pdf manual download. Badger Meter Recordall Disc Series Meters User Manual. Installation instructions. Badger Meter Accessories for water Manuals Directory ManualsDir.com - online owner manuals library Search.

Advertising

Cubic Meters

Cold Water Meters Badger Compound 2″ – 6″ Return to Cold Water Meters – Compound Recordall Compound Series Meters from Badger Meter combine two metering technologies in one innovative package. A positive displacement chamber measures low flow, while a turbine chamber records high flow. Compound Meter User Manual. Recordall Compound.

RECORDALL Disc Meters

Meter Size

Unit of

Measure

RTR Test

Circle (gal)

RTR Resolution

M25

5/8”,

3/4”

Cubic Meter

0.1

0.01

M35

3/4”

Cubic Meter

0.1

0.01

M40

1”

Cubic Meter

0.1

0.01

M70

1”

Cubic Meter

0.1

0.01

M70

1-1/2”

Cubic Meter

1

0.1

M120

1-1/2”

Cubic Meter

1

0.1

M170

2”

Cubic Meter

1

0.0

M180

2”

Cubic Meter

1

0.1

RECORDALL Turbo Series Meters

Meter Size

Unit of

Measure

RTR Test

Circle

RTR Resolution

T160

1-1/2”

Cubic Feet

1

0.1

T200

2”

Cubic Feet

1

0.1

T450

3”

Cubic Feet

1

0.1

T1000

4”

Cubic Feet

1

0.1

T2000

6”

Cubic Feet

10

1

T3500

8”

Cubic Feet

10

1

T5500

10”

Cubic Feet

10

1

T6200

12”

Cubic Feet

10

1

T6600

Badger Meter Recordall 6 User Manual Ios 11

16”

Cubic Feet

10

10

T10000

20”

Badger Meter Recordall 6 User Manual Pdf

Cubic Feet

100

10

RECORDALL Turbo II Meters

Meter Size

Unit of

Measure

RTR Test

Circle (gal)

RTR Resolution

T200

2”

Cubic Feet

1

0.1

T450

3”

Cubic Feet

1

0.1

T1000

4”

Cubic Feet

1

0.1

T2000

6”

Cubic Feet

10

1

T3500

8”

Cubic Feet

Badger Meter Recordall 6 User Manual Verizon

10

1

T5500

10”

Cubic Feet

100

10

T6200

12”

Cubic Feet

100

10

T6600

16”

Cubic Feet

10

1

T10000

20”

Cubic Feet

10

1

Advertising
Popular Brands
Popular manuals
Badger meter recordall model 25

Recordall® Turbo Series Meters Models 160 (1-1/2'), 200 (2'), 450 (3'), 1000 (4'), 2000 (6'), 3500 (8'), 5500 (10'), & 6200 (12'); NSF/ANSI Standards 61 and 372 Certified DESCRIPTION Recordall Turbo Series meters meet or exceed the most recent revision of AWWA Standard C701 Class II Standards and are available in a lead-free bronze alloy for sizes 1-1/2' through 10' and cast iron for 12' meters. Turbo Series meters comply with the lead-free provisions of the Safe Drinking Water Act. Sizes 1-1/2' through 10' meters are also certified to NSF/ANSI Standards 61 and 372 (Trade Designation: Turbo Series LL-NS) and carry the NSF-61 mark on the housing. All components of the lead-free alloy meter (housing, measuring element, seals and so on) comprise the certified system. Models 160 through 6200 are designed for 1-1/2' through 12' applications. These meters feature: • Direct coupled turbine based on an exclusive “floating rotor” design that reduces bearing friction—and associated wear and tear. Low pressure loss for improved system efficiency. Exceptional registration accuracy across low flow rate, normal operating flow rate and maximum continuous operation flow. Permanently sealed, tamper-resistant register or encoder. Integral strainer option for sizes 1-1/2' through 4' help protect your system from damaging debris and related downtime. Meters and encoders are compatible with Badger Meter AMR/AMI meter reading systems and other approved reading technologies. Applications: Recordall Turbo Series meters are designed for cold water, commercial and industrial applications where flows are consistent medium to high flows. Applications include hotels, apartment buildings, irrigations centers and manufacturing and processing plants. Turbo Series meters help reduce day-today maintenance costs while delivering accurate and efficient performance. Operation & Performance: Direct magnetic drive is achieved when the magnet carrier is driven by a gear train coupled to the rotor. The gear train consists of two sets of gears connected by a vertical transmission shaft. One gear set is at the magnet carrier, the other is a worm gear set at the rotor shaft. When water flows into the Turbo Series meter measuring element, it contacts the multi-vaned rotor. The resulting rotor rotation is then transmitted by magnetic coupling to a sealed register or encoder. The direct magnetic drive is built to provides a reliable meter-to-registration coupling. Tamper-Proof Features: Unauthorized removal of the register or encoder is inhibited by the option of a tamper detection seal wire screw, TORX® tamper-resistant seal screw or the proprietary tamper-resistant keyed seal screw. Each can be installed at the meter site or at the factory. Construction: The Recordall Turbo Series meter is constructed in compliance with ANSI and AWWA C701 standards. It consists of the following basic components: meter housing, interchangeable, unitized measuring element and permanently sealed direct reading registers or encoders. The measuring element consists of the transmission coupling, rotor, inlet and outlet straightening vanes with nose cones, and calibration ring assembly. The unique inlet and outlet straightening vanes minimize swirl from piping arrangements upstream as well as downstream. A strainer is recommended to help ensure optimal flow conditioning and protection for the measuring element. An integral strainer is available as an option for 1-1/2' through 4' meter sizes. The stainless steel strainer is built into the inlet end and includes a removable cover plate to permit easy access for routine cleaning. External strainers are available in sizes 2' through 12'. To simplify maintenance, the registers or encoders and measuring elements can be removed without removing the meter housing. Interchangeability of certain parts between meters also minimizes spare parts inventory investment. Meter Installation: The meter is designed for installations where flow is in one direction only. Companion flanges for installation of meters on various pipe types and sizes are available in cast iron or NL bronze as an option. See the Recordall Turbo Series Meters User Manual for specific instructions. Product Data Sheet